Part Number Hot Search : 
LA3607 34490JI 28C256 CA3082M M3R63TCJ ZMZ20M C3225 LTC20531
Product Description
Full Text Search
 

To Download AMEC30-15DMAZ Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  series amec30-maz 30 watt | ac-dc / dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.r 1 of 5 north america only features: models single output model input voltage (vac/hz) input voltage (vdc ) output voltage (v) output current max (a) efficiency (%) amec30-3.3smaz 90-264/47-440 130-370 3.3 6 80 amec30-5smaz 90-264/47-440 130-370 5 6 83 amec30-12smaz 90-264/47-440 130-370 12 2.5 85 amec30-15smaz 90-264/47-440 130-370 15 2 85 amec30-24smaz 90-264/47-440 130-370 24 1.25 84 models dual output model input voltage ( vac/hz) input voltage (vdc) output voltage (v) output current max (a) efficiency (%) amec30-5dmaz 90-264/47-440 130-370 5 3 81 amec30-12dmaz 90-264/47-440 130-370 12 1.25 84 AMEC30-15DMAZ 90-264/47-440 130-370 15 1 83 amec30-24dmaz 90-264/47-440 130-370 24 0.625 82 note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. input specifications parameters conditions typical maximum units current 115 vac ? ? ? ? ? q 0.5 w start-up time 117 ms output specifications parameters conditions typical maximum units voltage accuracy 2 % line regulation (ll-hl) 0.5 % load regulation 0-100% load single 1 % 0-100% load dual 2 cross regulation 25% load - 1 st out, 100% load ? 2 nd out 5 % maximum capacitive load depending of the model 470-23 000 f transient response deviation 25% load step 2 % of vout ripple & noise * 20mhz bandwidth 50 mv p-p hold-up time (min) 115vac 29 ms minimum load current 0 % of max * ripple & noise measured with 0.1 f m/c and 1 f e/c ? 4000vac i/o isolation ? energy star compliant ? medical switching power modules for pcb mounting ? rohs compliant ? operating temperature: -40 to +85c ? low ripple and noise ? universal input: 90-260vac, 47-440hz, or 130-370vdc ? ce, culus approvals cb ? click on series name for product info on aimtec.com
series amec30-maz 30 watt | ac-dc / dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.r 2 of 5 north america only isolation specifications parameters conditions typical rated units tested i/o voltage 60 sec 4000 vac isolation resistance >1000 m ? general specifications parameters conditions typical maximum units switching frequency 47 khz protection class class ii over current protection auto recovery 110 140 % over voltage protection zener diode clamp 110 % short circuit protection hiccup mode, indefinite short circuit restart auto recovery operating temperature with derating above 55oc -40 - +85 o c maximum case temperature 100 o c storage temperature -40 to +100 o c temperature coefficient 0.02 % / o c cooling free air convection humidity non condensing 95 % rh case material metal weight 270 g dimensions (l x h x w) 4.92 x 2.56 x 1.38 inch / 125.00 x 65.00 x 35.00 mm mtbf > 800,000 hrs (mil-hdbk -217f, t=+25 oc)/full load > 200,000 hrs (mil-hdbk -217f, t=at hi ghest operating temperature)/full load environment approval test parameters conditions shock wave form half sine wave acceleration amplitude 5gn bump duration 30 ms converter operation before and after test, body mounted (on chassis) number of bumps 18 (3 in each direction for every axis) vibration test mode sweep sine, 10-100hz, speed 0.05hz/s displacement 1 mm acceleration 3g, 3 loops 30min one cycle, 3h total, every axis tested converter operation before and after test, body mounted (on chassis) safety specifications parameters agency approvals culus, ce, cb standards medical electrical equipment iec\en\ul 60601-1, 2 x moop, csa-c22.2 no. 601.1- m90 information technology equipment en 60950-1:2006+a11:2009 emi - conducted and radiated emission en55011, class b harmonic current emissions iec/en 61000-3-2, class a voltage fluctuations and flicker iec/en 61000-3-3, (en60555-3) electrostatic discharge immunity iec 61000-4-2 level 3 rf, electromagnetic field immunity iec 61000-4-3 level 2 electrical fast transient/burst immunity iec 61000-4-4 level 3 surge immunity iec 61000-4-5 level 2 rf, conducted disturbance immunity iec 61000-4-6 level 2 power frequency magnetic field immunity iec 61000-4-8 level 2 voltage dips, short interruptions immunity iec 61000-4-11
series amec30-maz 30 watt | ac-dc / dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.r 3 of 5 north america only pin out specifications pin single dual 1 ac input (l) ac input (l) 2 ac input (n) ac input (n) 3 +v output +v output 4 -v output common 5 n.c. common 6 n.c. -v output dimensions
series amec30-maz 30 watt | ac-dc / dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.r 4 of 5 north america only optional din rail bracket derating
series amec30-maz 30 watt | ac-dc / dc-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8.r 5 of 5 north america only earth/ground connection emc en55022 cl ass b compliant application circuit the application circuit is emc compliant for any type of ea rth/ground connection: input ground co nnection, output ground connec tion as shown or both sides, which is not recommended if the product isolation is used as a safety feature. note: 1. datasheets are updated as needed and as such, specifications ar e subject to change without notic e. once printed or downloaded , datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency cert ifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an am bient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary an d may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control sys tems or other such applications which necessitate specific safety and regulatory standards ot her the ones listed in this datasheet. 7. warranty is in accordance with aimtec?s st andard terms of sale available at www.aimtec.com. l n 90-264vac amexw30 \ maz +vout -vout ???????? ? ?????????????? ?????? cx1 ???????? 0.6uf ?????? cx2 ???????? 0.6uf l1 35mh ase2501v \ g


▲Up To Search▲   

 
Price & Availability of AMEC30-15DMAZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X